1000GF1 500 / 600 Rpm Steam HFO Fired Power Plant With 3 Phase Alternator
Descrition:
Utilities and Independent power producers use our 0~60 MW power plants to generate power to the grids in the undeveloped, developing world and in remote areas. These plants are flexible to follow the actual load and produce the necessary electricity typically from diesel oil, heavy fuel oil, bio diesel and bi-fuel. High efficiency, low emissions and proven long-term reliability make our diesel oil power plants, heavy fuel oil power plant, and bi-fuel power plants suitable for baseload applications. Depending on your current load profile, ambient conditions and what fuel is available (diesel oil, heavy fuel oil, crude oil etc.) we make sure you will get the most productive and cost-effective solution
Our company offers a wide range of engines for stationary power generation, where their competitive first-cost, high energy efficiencies and low life-cycle costs underwrite success, ranges from baseload power plant, peaking power plant to industrial self-captive power plant in cement, textile, mining or oil and gas industries etc.
These engines comfortably meet current emission standards, and are able to comply with more strict national codes by adding emission reduction equipment.
.
Peaking power plant
Our power plants can start and ramp up to full load very rapidly, in less than minutes. They can start upon a grid or a large power plant after shut down, without any external input of energy. Due to very high simple cycle efficiency on part and full load, they can provide very competitive power regulation and spinning reserve services to large grids, which both require operation on partial load. These very same plants can be used for peaking services during peak electricity demand hours. Due to the high efficiencies and consequential low generation costs, our power plants create more revenues for its operators. The main fuel can be gas, LFO, HFO or a multi-fuel combination of these.
Industrial self-captive power plant
Many energy intensive industries find it attractive to improve their competitiveness by producing their energy in a local captive power plant and thereby reduce the energy costs. In some areas this improves also the availability of energy due to unstable grid conditions. Many of the industrial power plants operate, producing electricity and utilizing the waste heat of the generation process to produce steam, hot water and cooling. All this we can do for you.
Applications:
cement, textile, mining or oil and gas industries etc.
Competitive Advantage:
Our experts in application engineering and project management are the key to achieving very short construction times , builds turn-key power plant with an output up to 60MW as base load power plant, peaking power plant or industrial self-captive power plant in cement, textile, mining or oil and gas industries etc. The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency Hz |
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | |||||
1500 | 1600 | 1800 | |||||
1650 | 1760 | 1980 | |||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | |||
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | |||
1765 | 2000 | 1765 | 2000 | 2000 | |||
500 | 600 | 500 | 600 | 600 | |||
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark 1.the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification |
||||||||||
Model |
2400GF |
2500GF |
||||||||
Rated power, KW |
2400 |
2500 |
||||||||
Overload , KW |
2640 |
2750 |
||||||||
Rated voltage, V |
400 |
415 |
3300 |
6300 |
10500 |
400 |
415 |
3300 |
6300 |
10500 |
Rated current , A |
4330 |
4174 |
525 |
275 |
165 |
4511 |
4348 |
547 |
172 |
286 |
Frequency , Hz |
50 |
50 |
||||||||
Power factor |
0.8 Lagging |
0.8 Lagging |
||||||||
Phase |
3 |
3 |
||||||||
Diesel engine |
GN832000ZD |
GN8320ZD |
||||||||
Rated power, KW |
2648 |
2795 |
||||||||
Rated rev, rpm |
750 |
750 |
||||||||
Alternator |
3 phase alternator |
|||||||||
voltage fluctuation rate% |
±1.0 |
|||||||||
Frequency fluctuation rate, % |
+12, -10 |
|||||||||
Stable voltage regulating rate, % |
3 |
|||||||||
Transient voltage regulating rate, % |
+12, -10 |
|||||||||
Stable Frequency fluctuation rate, % |
4
|
|||||||||
Transient frequency regulating rate, % |
5 |
|||||||||
Stabilizing time, voltage , S |
+1 |
|||||||||
Stabilizing time, frequency , S |
+12, -10 |
|||||||||
voltage regulating method |
automatic and manual |
|||||||||
Frequency regulating method |
manual |
|||||||||
starting method |
compressed air |
|||||||||
Lubricating method |
pressure lubricating |
|||||||||
Cooking method |
water cooling |
|||||||||
coupling |
flexible |
|||||||||
Overdimension, mm |
8950*2570*6050 |
|||||||||
Weight, Kg |
45000 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position