Product Details:
Payment & Shipping Terms:
|
High Light: | oil fired power plant,diesel power plant |
---|
400V / 11KV / 23KV / 33KV Containerized HFO fired Power Plants
1. Being in the decentralized energy sector benefit from the experience of fuel treatment. Thereby many years of experience in power generation system integration and engineering applications guarantee customized solutions.
2. The kangwei container power station concept is an efficient and economic system designed for heavy fuel oil or gas fuelled applications.
For special fuel operation, the container represents an economic overall package consisting of a genset and auxiliary fuel processing, in two standardized container. Engineering and design are always adjusted to the requirements on special fuel operation.
The container is heat and noise insulated, and the slim, smooth wall design enables maximum utilisation of the interior space.
2. containerized diesel generator application as below
Outdoor operation
Semi-mobility (movability) possible
Supplying important consumer at grid failure
Power Plants
rough environment power supply
3. Advantages of kangwei containerized power generation
G300 Statinary Generating Sets Main Specification |
||||||||
Model |
1000GF1 |
1250GF3 |
1350GF4 |
1400GF4 | ||||
Rated power, KW |
1000 |
1250 |
1350 |
1400 | ||||
Overload , KW |
1100 |
1375 |
1485 |
1540 | ||||
Rated voltage, V |
400/415/440/3300/6300/10500/13800 |
|||||||
Rated current , A |
|
|
|
|
|
|||
Frequency , Hz |
50 |
60 |
50 |
60 |
50 |
60 | 50 | 60 |
Power factor |
0.8 Lagging |
|||||||
Phase |
3 |
|||||||
Diesel engine |
G6300ZD6 |
G6300ZD8 |
G8300ZD6 |
G6300ZD10 |
G8300ZD10 |
G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW |
1103 |
1470 |
1471 |
1471 |
1765 |
2000 | 1765 | 2000 |
Rated rev, rpm |
500 |
600 |
500 |
600 |
500 |
600 | 500 | 600 |
Alternator |
3 phase alternator |
|||||||
voltage fluctuation rate% |
<0.5 |
<0.5 |
||||||
Frequency fluctuation rate, % |
<0.5 |
<0.5 |
||||||
Stable voltage regulating rate, % |
±1.0 |
±1.0 |
||||||
Transient voltage regulating rate, % |
+20, -15 |
+20, -15 |
||||||
Stable Frequency fluctuation rate, % |
<3 |
<0.5 |
||||||
Transient frequency regulating rate, % |
+12, -10 |
|||||||
Stablizing time, voltage , S |
<4 |
|||||||
Stablizing time, frequency , S |
<3 |
|||||||
voltage regulating method |
automatic and munual |
|||||||
Frequency regulating method |
manual |
|||||||
starting method |
compressed air |
|||||||
Lubricating method |
pressue lubricating |
|||||||
Cooking method |
water cooling |
|||||||
coupling |
flexible |
|||||||
Overdimension, mm |
3880*2150*3180 |
8470*2360*3060 |
||||||
Weight, Kg |
30000 |
35000 |
38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification |
||||||||||
Model |
2400GF |
2500GF |
||||||||
Rated power, KW |
2400 |
2500 |
||||||||
Overload , KW |
2640 |
2750 |
||||||||
Rated voltage, V |
400 |
415 |
3300 |
6300 |
10500 |
400 |
415 |
3300 |
6300 |
10500 |
Rated current , A |
4330 |
4174 |
525 |
275 |
165 |
4511 |
4348 |
547 |
172 |
286 |
Frequency , Hz |
50 |
50 |
||||||||
Power factor |
0.8 Lagging |
0.8 Lagging |
||||||||
Phase |
3 |
3 |
||||||||
Diesel engine |
GN832000ZD |
GN8320ZD |
||||||||
Rated power, KW |
2648 |
2795 |
||||||||
Rated rev, rpm |
750 |
750 |
||||||||
Alternator |
3 phase alternator |
|||||||||
voltage fluctuation rate% |
±1.0 |
|||||||||
Frequency fluctuation rate, % |
+12, -10 |
|||||||||
Stable voltage regulating rate, % |
3 |
|||||||||
Transient voltage regulating rate, % |
+12, -10 |
|||||||||
Stable Frequency fluctuation rate, % |
4
|
|||||||||
Transient frequency regulating rate, % |
5 |
|||||||||
Stabilizing time, voltage , S |
+1 |
|||||||||
Stabilizing time, frequency , S |
+12, -10 |
|||||||||
voltage regulating method |
automatic and manual |
|||||||||
Frequency regulating method |
manual |
|||||||||
starting method |
compressed air |
|||||||||
Lubricating method |
pressure lubricating |
|||||||||
Cooking method |
water cooling |
|||||||||
coupling |
flexible |
|||||||||
Overdimension, mm |
8950*2570*6050 |
|||||||||
Weight, Kg |
45000 |
Remark
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position